Altivar Process drives are designed to adapt to the harshest environments.
- Ambient operating temperature
- wall-mounting drives:
-- IP 21 : - 15...+ 50 °C/+ 5...122 °F as standard
+ 50...60 °C/+ 122...140 °F with derating
-- IP 55 : - 15...+ 40 °C/+ 5...104 °F as standard
+ 40...50 °C/+ 104...122 °F with derating
-- a patented flange-mounting kit for evacuating outside the enclosure in which
it is mounted the heat dissipation from the power section (see page 23)
- floor-standing IP 21/IP 54 drives:
-- 0... + 40 °C/32... + 104 °F as standard
-- + 40...+ 50 °C/+ 104...122 °F with derating
- Storage and transport temperature: - 40…+ 70 °C/- 40…+ 158 °F
- Operating altitude:
- 0…1,000 m/0…3,281 ft without derating
- 1,000...4,800 m/3,281…15,748 ft with derating of 1% per 100 m/328 ft
- Withstand to harsh environments:
- Chemical class 3C3 conforming to IEC/EN 60721
- Mechanical class 3S3 conforming to IEC/EN 60721
- Electronic cards with protective coating
- Protection to suit requirements:
- IP 21/UL type 1 for wall mounting in a plant room and in an enclosure
- IP 55 for wall mounting, with protection against dust and water jets
- Floor-standing IP 21
- Floor-standing IP 54, with protection against dust and water jets
Was this helpful?