What are the part number and driver for the serial port (9-Pin D-Shell) to USB converter for Modicon Quantum PLC.
The part no. of the Schneider USB to RS232 Converter is TSXCUSB232 Refer the attachment for the TSXUSB232 documentation.   Use the standard Schneider...
Why does my USB drive show up as a Modicon PLC in the Device Manager?
 Issue: USB drive does not work properly and shows up as a Modicon PLC in the Device Manager of the PC.   Product Line: Modicon PLC   Environment:...
Where can I download SoMove and DTM files? What is the USB to RJ45 cable required to connect SoMove to the drive using the ModBus port?
Issue: Where can I find a link for SoMove? What cable is used? Product line: Variable Frequency Drives and Soft Starts   Environment: All models,...
M241/M251 Firmware update using Somachine Controller Assistant with SD Card
Issue: Looking for the procedure to update the firmware of M241/M251 using an SD card. Product Line: M241 M251 SoMachine Environment: SoMachine Controller...
I have the TCSMCNAM3M002P USB to RS485 converter cable, how can I download the drivers to use it?
For TCSMCNAM3M002P cable TSXCUSB and TCSMCNAM DRIVER need to be installed  The drivers can be downloaded from below link : https://www.schneider-electric.com/en/download/document/TSXCUSB+and+TCSMCNAM+DRIVER/...
How to calculate the scan time of Hot Stand-By (HSBY) system in Modicon Quantum range.
Considering the Hot Stand-By system, the scan time mainly comes from the addition of three parts:   Part 1: User application logic execution time,...
Which are the latest GSD file revisions for ProfibusDP communication board of the Altivar 71 Drive.
The latest GSD File revisions required for ProfibusDP communication board of the Altivar 71 Drive are as follows:  1. The correct revision of GSD...
Do Unity Pro and Unity Application Generator (UAG) have separate licenses.
Yes, Unity Pro and UAG have separate licenses.   During installation of UAG, it detects the existing Unity Pro versions on your PC/Laptop and it will...
Is it possible to write a new IP address of connected device at runtime in Vijeo Designer.
Yes, it is possible to write a new IP address of connected devices via scripting during runtime. This feature has been implemented in Vijeo Designer...
Is it SDI-12 protocol supported in SCADAPack controllers?
The SDI-12 protocol is a master-slave protocol and SCADAPack 32 or SCADAPack 3xx series controller can be used as a master to communicate with slave...