Preventa XU - XUSL2E and XUSL4E EC/EU declaration of conformity
Please find attached 2018 EC/EU declarations of conformity for our XUSL4E, XUSL2E, XUSL4MA & XUSL4MB safety light curtains
What is the MTTF of Altivar 61 and Altivar 71.
Refer the attachment for the data of Mean Time To Fail (MTTF) for Altivar 61 and Altivar71 Drives.
Preventa XY2C - EC/EU declaration of conformity for the E.stop rope pull switches XY2CJ
Find attached our EC/EU declaration of conformity for the E.stop rope pull switches XY2CJ, dated on july 2018
XCSLF XCSLE safety switches - EC/EU declaration of conformity
Find attached 2018 EC/EU declaration of conformity for our XCSLF & XCSLE safety switches
What is the heat dissipation of the Altivar 61 Drive when it is in Ready state.
The heat dissipation value of the Altivar 61 Drives when in Ready State (RDY - Drive is powered up but motor is not running) depends on the size of...
What is the minimum recommended Ground to Input Phase insulation resistance for Altivar 71 Drive.
The Insulation resistance value between Ground to Input Phase should be greater than 1 Mega Ohms which is the Megger value at 500 V for 1 minute.
What is the naming convention for Vijeo Designer application.
The following characters are valid characters that can be used for naming parts, devices, object, variables and passwords in Vijeo-Designer.   a)...
Are the TeSys-T motor management relays comply with related EMC standards? Please provide necessary document?
Yes, the Tesys T comply to the various IEC/EN standards below related to electromagnetic interference. Please refer the attached characteristic pages...
Do Unity Pro and Unity Application Generator (UAG) have separate licenses.
Yes, Unity Pro and UAG have separate licenses.   During installation of UAG, it detects the existing Unity Pro versions on your PC/Laptop and it will...
What is the Short Circuit rating of LU2B starters in TeSys U as per UL508 TypeE specification?
The Short Circuit rating of LU2B starters in TeSys U as per UL508 TypeE specification is as follows:   Voltage (V AC) Short Circuit Rating (KA) 440...