
switch-disconnector Masterpact NW08HF - 800 A - 690 V - 4 poles - drawout
Show more characteristics >-
Characteristics
Main range Masterpactproduct name Masterpact NWproduct or component type Switch disconnectordevice short name Masterpact NW08switch-disconnector name Masterpact NW08HFdevice application Protectionpoles description 4Pnetwork type ACnetwork frequency 50/60 Hz[Ie] rated operational current 800 A AC 50/60 Hz 690 V[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-3[Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-3[Icm] rated short-circuit making capacity 187 kA 220...690 V AC 50/60 Hz[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-3breaking capacity code HFsuitability for isolation Yes conforming to IEC 60947-3contact position indicator Yesvisible break Nopollution degree 4 conforming to IEC 60664-1Complementary control type Push-buttonmounting mode Drawoutmounting support Chassis[Icw] rated short-time withstand current 50 kA ( 3 s ) conforming to IEC 60947-385 kA ( 1 s ) conforming to IEC 60947-3mechanical durability 12500 cycles without maintenance conforming to IEC 60947-325000 cycles with maintenance conforming to IEC 60947-3electrical durability AC-23A : 10000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-3AC-23A : 10000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3AC-3 : 6000 cycles 440/690 V AC 50/60 Hz without maintenance conforming to IEC 60947-3connection pitch 115 mmheight 352 mmwidth 537 mmdepth 297 mmproduct weight 80 kgEnvironment standards IEC 60947-3product certifications ASEFAASTAambient air temperature for operation -25...70 °Cambient air temperature for storage -35...85 °CContractual warranty Warranty period 18 months 18 months -
Documents and Downloads
Language- English
User guideSizeAdd to My DocumentsCircuit breakers and switch-disconnnectors Masterpact NW08-63 (Version 07)CADSizeAdd to My DocumentsBasic switch-disconnector Masterpact NW08 to NW40 4P; withdrawable device (Version 1.0)Date 4/25/13Size 289 KBDate 4/25/13Size 613 KBswitch disconnector Masterpact NT (Version 1.0)CAD files for 48243: Basic switch-disconnector Masterpact NW08 to NW40 4P; withdrawable device (Version 1.0)CAD files for 48243: Basic switch-disconnector Masterpact NW08 to NW40 4P; withdrawable device (pdf)Date 2/4/19Size 298.3 KBCertificateSizeAdd to My DocumentsCertificate of conformity MASTERPACT NW08-NW10-NW12-NW16 TYPE HF according to IEC 60947-2:2009 and BS EN 60947-2:2006 + A1:2009 (Version 1.0)Date 12/13/17Size 610.1 KBInstruction sheetSizeAdd to My DocumentsFixed and drawout circuit breaker - Masterpact NW (Version 12)End of Life InformationSizeAdd to My DocumentsEoLI-Masterpact NW 25 H1 three pole draw out circuit breaker with Micrologic 5.0A control unit (Version 1.0)EoLI-Masterpact NW 25 H1 three pole draw out circuit breaker with Micrologic 5.0A control unit (pdf)Date 9/21/17Size 767.7 KBEnd-of-Life Instructions Masterpact NW (Version 1.0)Product Environmental ProfileSizeAdd to My DocumentsPEP-Masterpact NW 25 H1 three pole draw out circuit breaker with Micrologic 5.0A control unit (Version 1.0)Date 11/20/17Size 290.1 KBPEP Masterpact NW08 to NW40 circuit breaker (Version 1.1) -
Technical FAQs
No results foundUnfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.