Gulf countries and Pakistan

Schneider Electric Gulf Countries and Pakistan Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Choose another country or region

ABE7R16T212 Product picture Schneider Electric

View all Modicon ABE7

Modicon ABE7 - ABE7R16T212

Interfaces for PLCs

ABE7R16T212 Product picture Schneider Electric
View all Modicon ABE7
Modicon ABE7 - ABE7R16T212
Interfaces for PLCs

Sub-base with plug-in electromechanical relay ABE7 - 16 channels - relay 10 mm

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Advantys Telefast ABE7
    product or component type
    Sub-base with plug-in electromechanical relay
    sub-base type
    Output sub-base
    [Us] rated supply voltage
    19...30 V conforming to IEC 61131-2
    number of channels
    16
    Complementary
    supply circuit type
    DC
    product compatibility
    ABR7S21
    contacts type and composition
    1 NO
    status LED
    1 LED per channel, green for channel status
    1 LED, green for power ON
    polarity distribution
    Polarity distribution contact common per 2 groups of 8 channels
    short-circuit protection
    1 A internal fuse, 5 x 20 mm, fast blow (PLC end)
    0.5 A fuse per channel, 5 x 20 mm, fast blow (output circuit)
    fixing mode
    By clips on 35 mm symmetrical DIN rail
    By screws on solid plate with fixing kit
    supply current
    <= 1 A
    voltage drop on power supply fuse
    0.3 V
    [Ui] rated insulation voltage
    2000 V between terminals/mounting rails
    300 V between coil circuit/contact circuits conforming to IEC 60947-1
    [Uimp] rated impulse withstand voltage
    2.5 kV
    installation category
    II conforming to IEC 60664-1
    tightening torque
    0.6 N.m (withflat Ø 3.5 mm
    product weight
    0.73 kg
    Environment
    product certifications
    BV
    CSA
    DNV
    GL
    LROS (Lloyds register of shipping)
    UL
    IP degree of protection
    IP2x conforming to IEC 60529
    resistance to incandescent wire
    750 °C conforming to IEC 60695-2-11
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
    vibration resistance
    2 gn (f = 10...150 Hz) conforming to IEC 60068-2-6
    resistance to electrostatic discharge
    4 kV (contact) conforming to IEC 61000-4-2 level 3
    8 kV (air) conforming to IEC 61000-4-2 level 3
    resistance to radiated fields
    10 V/m (26000000...1000000000 Hz) conforming to IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV conforming to IEC 61000-4-4 level 3
    ambient air temperature for operation
    -5...60 °C conforming to IEC 61131-2
    ambient air temperature for storage
    -40...80 °C conforming to IEC 61131-2
    pollution degree
    2 conforming to IEC 60664-1
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Catalogue
    Date
    Size
    Add to My Documents
    Date 7/14/18
    Size 8.8 MB
    CAD
    Date
    Size
    Add to My Documents
    Premium automation platform - Telefast 2 - Sub-bases
    Premium automation platform - Telefast 2 - Sub-bases
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Date 8/22/18
    Size 1.7 MB
    End of life manual
    Date
    Size
    Add to My Documents
    Marine certificate
    Date
    Size
    Add to My Documents
    Date 6/14/16
    Size 80.5 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    (1)
    ABE7BV10 / BV20, ABE7BV10E / BV20E


  • Mounting and Clearance

    Mounting



  • Connections and Schema

    HE10 16 Channels



    Wiring Diagram


    (1)
    Inductive load
    (2)
    ABR7S21 (1 “F” "SPST") Ith = 5 A (supplied)


  • Performance Curves

    Curves for Determining Cable Type and Length According to the Current
    16-channel Sub-base


    L
    Cable length
    IT
    Total current per sub base (A)
    IA
    Average current per channel (mA)
    (1)
    TSXCDP••2 and ABFH20H••0 cables with c.s.a. 0.08 mm2 (AWG 28).
    (2)
    TSXCDP••3 cables with c.s.a. 0.34 mm2 (AWG 22).
    (3)
    Cables with c.s.a. 0.13 mm2 (AWG 26).

    The curves are given for a voltage drop of 1 V in the cable. For n volts tolerance, multiply the length determined from the graph by n.


    Temperature Derating Curves


    (1)
    100 % of channels used
    (2)
    50 % of channels used


    Electrical Durability (in Millions of Operating Cycles) Conforming to IEC 60947-5-1

    Multiply all durability values by 0.75 for ABR7S23.

    DC Loads

    DC12 curves


    DC12
    control of resistive loads and of solid state loads isolated by optocoupler, l/R ≤ 1 ms.

    DC13 curves


    DC13
    switching electromagnets, L/R ≤ 2 x (Ue x Ie) in ms, Ue: rated operational voltage, Ie: rated operational current (with a protective diode on the load, DC12 curves must be used with a coefficient of 0.9 applied to the number in millions of operating cycles)

    AC Loads

    AC12 curves


    AC12
    control of resistive loads and of solid state loads isolated by optocoupler, cos ϕ ≥ 0.9.

    AC14 curves


    AC14
    control of small electromagnetic loads ≤ 72 VA, make: cos ϕ = 0.3, break: cos ϕ = 0.3.

    AC15 curves


    AC15
    control of electromagnetic loads > 72 VA, make: cos ϕ = 0.7, break: cos ϕ = 0.4.