    range of product
    Advantys Telefast ABE7
    product or component type
    Solid state input relay sub-base
    [Us] rated supply voltage
    230/240 V AC 50/60 Hz (sensor end)
    24 V DC (PLC end)
    number of channels
    16
    number of terminal per channel
    2
    connections - terminals
    Spring terminal, clamping capacity: 1 x 0.09...1 x 1.5 mm² AWG 28...AWG 16 flexible with cable end
    Spring terminal, clamping capacity: 1 x 0.14...1 x 2.5 mm² AWG 26...AWG 12 solid
    Spring terminal, clamping capacity: 1 x 0.14...1 x 2.5 mm² AWG 26...AWG 14 flexible without cable end
    Complementary
    terminal block type
    Removable
    supply voltage limits
    264 V AC (sensor end) conforming to IEC 61131-2
    19...30 V DC (PLC end) conforming to IEC 61131-2
    isolation PLC/operative part
    Yes
    protection type
    Internal fuse of 1 A (5 x 20 mm), fast blow type at PLC end
    Adjustable by external fuse, fast blow type at sensor end
    fixing mode
    By clips on 35 mm symmetrical DIN rail
    By screws on solid plate with fixing kit
    current per channel
    0.008 A
    current state 0 guaranteed
    <= 2 mA (sensor end)
    voltage state 0 guaranteed
    <= 40 V (sensor end)
    current state 1 guaranteed
    >= 4.5 mA sensor end
    voltage state 1 guaranteed
    >= 164 V (sensor end)
    maximum switching current
    15 mA (PLC end)
    minimum switching current
    1 mA (PLC end)
    residual current
    <= 0.1 mA at state 0 (PLC end)
    voltage drop
    <= 1 V at state 1 (PLC end)
    response time
    <= 20 ms from state 0 to 1
    <= 20 ms from state 1 to 0
    switching frequency
    <= 25 Hz duty cycle: 50 %
    [Uimp] rated impulse withstand voltage
    2.5 kV IEC 60947-1
    [Ui] rated insulation voltage
    2000 V
    installation category
    II conforming to IEC 60664-1
    tightening torque
    0.6 N.m (with flat Ø 3.5 mm)
    product weight
    0.407 kg
    Environment
    dielectric strength
    2000 V 50/60 Hz conforming to IEC 60947-1
    standards
    IEC 61131-2 Type 1
    IP degree of protection
    IP2x conforming to IEC 60529
    resistance to incandescent wire
    750 °C, extinction time: <= 30 s conforming to IEC 60695-2-11
    shock resistance
    15 gn 11 ms IEC 60068-2-27
    vibration resistance
    2 gn (f = 10...150 Hz) conforming to IEC 60068-2-6
    resistance to electrostatic discharge
    4 kV contact level 3 IEC 61000-4-2
    8 kV air level 3 IEC 61000-4-2
    resistance to radiated fields
    10 V/m (26000000...1000000000 Hz) conforming to IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV conforming to IEC 61000-4-4 level 3
    ambient air temperature for operation
    -5...60 °C conforming to IEC 61131-2
    ambient air temperature for storage
    -40...80 °C conforming to IEC 61131-2
    pollution degree
    2 conforming to IEC 60664-1
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    CAD
    Date
    Size
    Add to My Documents
    Premium automation platform - Telefast 2 - Sub-bases
    Premium automation platform - Telefast 2 - Sub-bases
    End of life manual
    Date
    Size
    Add to My Documents
    Marine certificate
    Date
    Size
    Add to My Documents
    Date 6/14/16
    Size 80.5 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    (1)
    ABE7BV20 / ABE7BV20E


  • Mounting and Clearance

    Mounting



  • Connections and Schema

    HE10 16 Channels



    Wiring Diagram


    ABE7

    U1, U2

    S16E2B1 / E2B1E

    24 VDC

    S16E2E1 / E2E1E

    48 VDC

    S16E2E0 / E2E0E

    48 VAC

    S16E2F0 / E2F0E

    115 VAC

    S16E2M0 / E2M0E

    230 VAC


  • Performance Curves

    Curves for Determining Cable Type and Length According to the Current
    16-channel Sub-base


    L
    Cable length
    IT
    Total current per sub base (A)
    IA
    Average current per channel (mA)
    (1)
    TSXCDP••2 and ABFH20H••0 cables with c.s.a. 0.08 mm2 (AWG 28).
    (2)
    TSXCDP••3 cables with c.s.a. 0.34 mm2 (AWG 22).
    (3)
    Cables with c.s.a. 0.13 mm2 (AWG 26).

    The curves are given for a voltage drop of 1 V in the cable. For n volts tolerance, multiply the length determined from the graph by n.