sub-base - soldered solid state output relay ABE7 - 16 outputs - 0.5 A

Show more characteristics >
Add to My Products Remove from My Products

  • Main
    range of product
    Advantys Telefast ABE7
    product or component type
    Solid state output relay sub-base
    [Us] rated supply voltage
    24 V DC (PLC end)
    24 V DC (preactuator end)
    number of channels
    16
    relay type
    Soldered solid state relay
    Complementary
    terminal block type
    Removable
    isolation PLC/operative part
    No
    fixing mode
    By clips on 35 mm symmetrical DIN rail
    By screws on solid plate with fixing kit
    width
    125 mm
    current state 0 guaranteed
    0.4 mA (PLC end)
    voltage state 0 guaranteed
    3.4 V (PLC end)
    current state 1 guaranteed
    3.1 mA (PLC end)
    voltage state 1 guaranteed
    16.9 V (PLC end)
    current per output common
    <= 9 A
    current per channel
    0.5 A (preactuator end)
    minimum switching current
    1 mA
    drop-out voltage
    <= 0.3 V (preactuator end)
    maximum switching current
    700 mA DC-12
    700 mA DC-13
    tungsten load
    10 W DC-6
    residual current
    <= 0.5 mA (preactuator end)
    fault type
    Overload
    Short-circuit
    fault indication
    Without
    switchable inductive energy L/R
    <= 400(U.I) ms
    circuit breaker threshold
    >= 0.75 A
    response time
    <= 0.1 ms from state 1 to 0
    <= 0.2 ms from state 0 to 1
    switching frequency
    < 0.6/LI² Hz
    installation category
    II conforming to IEC 60664-1
    tightening torque
    0.6 N.m (withflat Ø 3.5 mm
    product weight
    0.4 kg
    Environment
    product certifications
    BV
    CSA
    DNV
    GL
    LROS (Lloyds register of shipping)
    UL
    IP degree of protection
    IP2x conforming to IEC 60529
    protective treatment
    TC
    resistance to incandescent wire
    750 °C, extinction time: < 30 s conforming to IEC 60695-2-11
    shock resistance
    15 gn for 11 ms conforming to IEC 60068-2-27
    resistance to radiated fields
    10 V/m (26000000...1000000000 Hz) conforming to IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV conforming to IEC 61000-4-4 level 3
    ambient air temperature for operation
    -5...60 °C conforming to IEC 61131-2
    ambient air temperature for storage
    -40...80 °C conforming to IEC 61131-2
    pollution degree
    2 conforming to IEC 60664-1
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • French
    • Italian
    • German
    Catalogue
    Date
    Size
    Add to My Documents
    Telefast pre-wiring system: Modicon ABE7 and Modicon ABE9 (Version 2.0)
    CAD
    Date
    Size
    Add to My Documents
    Premium automation platform - Telefast 2 - Sub-bases (Version 1.0)
    Premium automation platform - Telefast 2 - Sub-bases (Version 1.0)
    Instruction sheet
    Date
    Size
    Add to My Documents
    ABE7S16S... Sub-bases with soldered solid state outputs, plug-in terminal blocks (Version 06)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    NHA4191010.xx_DeclarationOfConformity_ABE7_ABR7_ABS7 (Version 1.0)
    End of Life Information
    Date
    Size
    Add to My Documents
    ABE7.... Modicon Telefast, pre-wired system, Product End-of-Life Instructions (Version 1.0)
    ABE7.... Modicon Telefast, pre-wired system, Product End-of-Life Instructions (Version 2.0)
    Marine certificate
    Date
    Size
    Add to My Documents
    DNV GL Type Approval Telefast (Version 1.0)
    Date 6/14/16
    Size 80.5 KB
  • Technical FAQs

    No results found
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    (1)
    ABE7BV20 / ABE7BV20E


  • Mounting and Clearance

    Mounting



  • Connections and Schema

    HE10 16 Channels



    Wiring Diagram


    (1)
    Inductive load
    (2)
    AB1FUSE435U5X + quick acting FUSE 5 x 20 type F.


  • Performance Curves

    Curves for Determining Cable Type and Length According to the Current
    16-channel Sub-base


    L
    Cable length
    IT
    Total current per sub base (A)
    IA
    Average current per channel (mA)
    (1)
    TSXCDP••2 and ABFH20H••0 cables with c.s.a. 0.08 mm2 (AWG 28).
    (2)
    TSXCDP••3 cables with c.s.a. 0.34 mm2 (AWG 22).
    (3)
    Cables with c.s.a. 0.13 mm2 (AWG 26).

    The curves are given for a voltage drop of 1 V in the cable. For n volts tolerance, multiply the length determined from the graph by n.